最新的Huawei HCIP-Storage V5.5 - H13-624_V5.5免費考試真題
問題1
A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on storage devices. Which of the following statements is false about the engineer's configuration?
正確答案: C
說明:(僅 VCESoft 成員可見)
問題2
In Huawei OceanStor Dorado series storage, disks, controllers, CPUs, memory modules, interface modules, and power modules are replaceable units and can be hot-swapped.
正確答案: A
說明:(僅 VCESoft 成員可見)
問題3
When purchasing storage devices, which of the following criteria will an enterprise use to evaluate the storage devices? (Multiple choice)
正確答案: B,C,D
問題4
An industry customer purchased two OceanStor Dorado 18000 series storage systems for service deployment. To ensure high service reliability, an engineer configured the HyperMetro feature on the storage systems. The arbitration mode is static priority mode, and storage A is the preferred site and storage B is the non-preferred site. If the link between storage A and storage B is down, what is the arbitration result?
正確答案: D
說明:(僅 VCESoft 成員可見)
問題5
In Huawei converged storage, availability refers to the capability of a system to quickly recover the operating environment from damage. If the availability of the storage product is 99.9999%, what is the downtime within one year?
正確答案: A
說明:(僅 VCESoft 成員可見)
問題6
A financial customer has purchased several Huawei flash storage devices to deploy HyperMetro services. During operation and maintenance, an engineer discovers that the health status of a HyperMetro vStore pair is faulty. This indicates that the running status of the HyperMetro vStore pair is invalid or unsynchronized.
正確答案: A
說明:(僅 VCESoft 成員可見)
問題7
During routine inspection, engineers find that several faults occur on Huawei all-flash storage and need to rectify the faults. Which of the following is not a basic troubleshooting principle for storage systems?
正確答案: B
說明:(僅 VCESoft 成員可見)
問題8
In Huawei container storage solution, CSI is short for Container Storage Interface. Which of the following statements is false about Huawei CSI?
正確答案: C
說明:(僅 VCESoft 成員可見)
問題9
FILL BLANK
In actual service scenarios, the characteristics of engineering, seismic, and geological data are similar to those of database backups. These types of data are stored in the same format but contain little duplicate data. In this case, the ______ feature of flash storage can be used to save storage space, thereby reducing investment and O&M costs.
In actual service scenarios, the characteristics of engineering, seismic, and geological data are similar to those of database backups. These types of data are stored in the same format but contain little duplicate data. In this case, the ______ feature of flash storage can be used to save storage space, thereby reducing investment and O&M costs.
正確答案:
Compression
Explanation:
When data has little duplicate content but similar formats, compression can effectively reduce the data size by encoding redundant patterns within the data itself, thereby saving storage space and lowering investment and O&M costs.
Explanation:
When data has little duplicate content but similar formats, compression can effectively reduce the data size by encoding redundant patterns within the data itself, thereby saving storage space and lowering investment and O&M costs.
問題10
In RAID 2.0+, chunk groups are generally divided into 32 KB grains, which is the smallest granularity used by volumes.
正確答案: B
說明:(僅 VCESoft 成員可見)
問題11
FILL BLANK
The LUN active-active balancing feature of Huawei all-flash storage integrates the global
________ design. The front-end interface board evenly distributes I/Os to the target controller for load balancing.
The LUN active-active balancing feature of Huawei all-flash storage integrates the global
________ design. The front-end interface board evenly distributes I/Os to the target controller for load balancing.
正確答案:
Cache
Explanation:
The LUN active-active balancing feature in Huawei all-flash storage integrates the global cache design, allowing both controllers to access shared cache resources. This enables the front-end interface board to evenly distribute I/Os across controllers, achieving optimal load balancing and high performance.
Explanation:
The LUN active-active balancing feature in Huawei all-flash storage integrates the global cache design, allowing both controllers to access shared cache resources. This enables the front-end interface board to evenly distribute I/Os across controllers, achieving optimal load balancing and high performance.

