最新的 Network Appliance NCIE-SAN NS0-504 免費考試真題:
1. Node 1 in a clustered pair detects that it has lost connectivity to one of its disk shelves. Node 1 is still up, but it cannot see one of its disk shelves. However, the partner node, Node 2, can see all of the Node 1's disk shelves. Which feature will cause Node 2 to monitor this error condition for a period of three minutes by default, and then forcibly take over Node 1 if the error condition persists?
A) Negotiated Fail Over
B) Auto enable of giveback
C) Takeover on panic
D) Cf.quickloop.enable
2. Which three are pre-requisites for using SnapRestore? (Choose three.)
A) The volume to be reverted must be offline.
B) The volume to be reverted must not be a SnapMirror destination.
C) Snapshot copies must exist on the storage system so that you can select a snapshot for the reversion.
D) You must enter the SnapRestore license code before you can use it.
3. Which statement is NOT true regarding NetApp Snapshots of VMware ESX datastores?
A) For VMDKs on VMFS datastores, to restore a specific VMDK requires a copy from the NetApp Snapshot to the datastore.
B) A NetApp Snapshot captures the entire FlexVol including information NOT associated with VMDKs.
C) NetApp Snapshots can be employed to backup VMFS, NFS, or RDM datastores.
D) NetApp Snapshots are instantaneous, so they always produce an application consistent image
4. You are troubleshooting a clustered failover problem at a customer site. The customer explains that both storage systems were NFS mounted onto the Solaris host. While in takeover mode, you attempt to create a file on the NFS mount point for the inaccessible system, but you get the following error:
NFS server filer2 not responding still trying.
When not in takeover mode, both storage systems operate normally and you do not get the error. You perform a "cf giveback" and you can now create a file over NFS on both systems. What should you do first to resolve this issue?
A) Replace the cluster interconnect card and run diagnostics "all" to ensure proper system operation.
B) Submit a new bug report.
C) Use the cluster-config-checker.cgi to identify the problem and corrective action.
D) Replace the NIC adapter.
5. Using the output below, a co-worker determined that these are types "Solaris" LUNs. What would your destination be?
lun show - m LUN patch mapped to LUN ID ------------------------------------------------------
/vol/vol1/lun0 solaris - igroup0 0 /vol/vol1/lun solaris- igroup1
0 /vol/vol1/qtree1/lun2 solaris - igroup2 0 /vol/vol1/qtree1/lun3 solaris - igroup3 0
A) Not enough information is given here. Run the lun show -v command to get the information requested.
B) These are type "Solaris" LUNs.
C) Not enough information is given here. Run the lun status command to get the information requested.
D) Not enough information is given here. Run the lun map command to get the information requested.
問題與答案:
| 問題 #1 答案: D | 問題 #2 答案: B,C,D | 問題 #3 答案: D | 問題 #4 答案: C | 問題 #5 答案: B |

下載最新試用版
1222位客戶反饋
我們對我們的產品非常有信心,所以我們不提供会给客户带去麻煩的產品。








120.108.136.* -