Network Appliance NS0-513 考試概覽:
| 認證廠商: | NetApp (Network Appliance) |
|---|---|
| 考試名稱: | NetApp 認證實作工程師,資料保護 |
| 考試代碼: | NS0-513 |
| 支援語言: | English |
| 考試時間: | 90 分鐘 |
| 實際考試題數: | 60-70 |
| 證照有效期限: | 2 年 |
| 及格分數: | 66% |
| 考試形式: | 多選題, 單選題 |
| 考試費用: | 150 USD |
| 相關認證: | NetApp 認證資料管理師 (NCDA) |
| 推薦課程: | NetApp 學習服務 |
| 考試報名: | Pearson VUE 報名作業 |
| 範例考題: | Network Appliance NS0-513 範例考題 |
| 考試方式: | 線上遠端監考或至 Pearson VUE 考場應考 |
| 必備條件: | 建議具備有效 NetApp 認證資料管理師 (NCDA) 資格;且擁有 6–12 個月 ONTAP 資料保護的實務操作經驗 |
| 官方大綱網址: | https://www.netapp.com/support-and-training/netapp-learning-services/certifications/ |
Network Appliance NS0-513 考試大綱主題:
| 章節 | 權重 | 目標 |
|---|---|---|
| ONTAP 核心資料保護功能 | 30% | - 設定與管理 Snapshot 技術 - 設定 SnapMirror 複製功能 - 具備保護機制的資料效率功能 - 建置 SnapVault 備份關聯 |
| 資料保護解決方案 | 25% | - 評估資料保護需求 - 確認解決方案的相依性與限制條件 - 設計並記錄資料保護架構 |
| 疑難排解與最佳化 | 5% | - 診斷複製相關問題 - 最佳化保護作業效能 |
| 業務持續性與災難復原 | 25% | - 同步與非同步複製模式 - 故障切換與回復作業程序 - 建置 MetroCluster 組態 - SVM 災難復原 (SVM-DR) |
| 資料保護軟體與工具 | 15% | - 與第三方備份工具整合 - 部署與管理 SnapCenter - 監控與驗證保護作業 |
最新的 NCIE-Data-Protection NS0-513 免費考試真題:
You have created a new CIFS share but it is inaccessible. After verifying the export policy, network connectivity, junction path, and permissions are all correct, you realize there is root volume loadsharing mirror in place.
What should you do next to make the share accessible?
Response:
- A. Update the root volume policy.
- B. Modify the CIFS share permissions.
- C. Re-create the CIFS share.
- D. Update load-sharing mirror.
答案:C 🗳️
Your customer wants to ensure that the SnapMirror relationships are easily managed in a bidirectional, multi-cluster environment. Which version of clustered Data ONTAP would you recommend?
- A. clustered Data ONTAP 8.2.3
- B. clustered Data ONTAP 9.1
- C. clustered Data ONTAP 8.1.4
- D. clustered Data ONTAP 8.3
答案:B 🗳️
You are installing a MetroCluster for clustered Data ONTAP consisting of FAS8080s. How are the high-availability interconnects cabled?
- A. High-availability interconnects are cabled both locally and remotely between the nodes.
- B. High-availability interconnects between the nodes are not needed.
- C. Each high-availability pair controller is cabled to its local partner.
- D. High-availability interconnects are only needed for the remote connections between the nodes.
答案:A 🗳️
You and other administrators are in the habit of creating FlexClone LUNs and then not deleting them when they are no longer needed. What should you do to help manage space utilization?
- A. Use the volume snapshot autodelete modify command.
- B. Configure FlexClone LUNs to automatically delete when they are one minute older than 30 days.
- C. Configure FlexClone LUNs to automatically be marked for deletion.
- D. Use the flexclone split command.
答案:A 🗳️
正在檢視第 1 頁(共 31 頁)。
正在檢視第 1-5 題(共 152 題)。

下載最新試用版
我們對我們的產品非常有信心,所以我們不提供会给客户带去麻煩的產品。


0位客戶反饋


