Nutanix NCM-MCI-6.10 考試概覽:
| 認證廠商: | Nutanix |
| 考試名稱: | Nutanix Certified Master - Multicloud Infrastructure |
| 考試代碼: | NCM-MCI-6.10 |
| 證照有效期限: | 3年 |
| 考試時間: | 180 minutes |
| 考試形式: | 選擇題, 情境導向題, 狀況判斷題 |
| 實際考試題數: | 60 |
| 考試費用: | 199美元 |
| 相關認證: | Nutanix Certified Master - Multicloud Infrastructure |
| 及格分數: | 3000 |
| 支援語言: | English |
| 範例考題: | Nutanix NCM-MCI-6.10 範例考題 |
| 考試方式: | 線上遠端監考或於Pearson VUE考場應試 |
| 必備條件: | Nutanix建議考生具備在企業環境中實際操作Nutanix解決方案的豐富經驗。建議先取得NCP-MCI認證,惟非強制要求。 |
| 官方大綱網址: | https://www.nutanix.com/support-services/training-certification/certifications |
Nutanix NCM-MCI-6.10 考試大綱主題:
| 章節 | 目標 |
|---|---|
| 設定與管理Nutanix網路功能 | - AHV網路設定 - 網路區隔與微分段技術 - 進階網路應用情境 |
| 複雜問題的疑難排解與解決 | - 叢集健康狀態管理 - 故障復原作業程序 - 記錄檔分析與診斷 |
| 部署與升級Nutanix環境 | - 叢集安裝與設定 - 軟體與韌體升級 - Foundation作業流程 |
| 導入與管理資安與法規遵循機制 | - 資安強化設定 - 存取控制與身分驗證 - 法規遵循架構 |
| 分析與修正效能問題 | - 效能監控與指標分析 - 網路效能疑難排解 - 儲存效能疑難排解 |
| 管理與設定Nutanix虛擬基礎架構 | - 資源排程與最佳化 - 虛擬機管理與操作 - AHV叢集設定 |
| 管理與最佳化Nutanix儲存功能 | - 儲存最佳化與使用效率 - 儲存容器與VDisk管理 - 資料保護與災難復原 |
最新的 Master Level NCM-MCI-6.10 免費考試真題:
1. An administrator is experiencing an unidentified issue which is causing inode exhaustion on CVMs in Cluster
1. The time between receiving alerts and exhaustion is too short; the administrator needs to lower the alert thresholds to allow more time to clean up inodes until the issue has been identified and resolution implemented.
From Prism Element, modify the appropriate alert policy setting critical threshold for Cluster 1 to 60% and warning threshold to 45%. Ensure the check runs every minute and is not resolved without administrator action.
2. Your security team is working on automation to manage Security Policies.
They have exported some of the existing rules to the file "Security Policy.txt" located on the desktop. This file needs to be modified for the test environment.
* All rules except the quarantine rule should be logged.
* Only the Quarantine rule should be enforced, the other rules will only be logged.
* The quarantine rule should affect the SecOps environment.
* The SMB rule should only affect VMs with the "smbhost" and "smbclient" tags.
* The "DN test" policy should allow ipv6 and should not restrict any protocols between the included tiers.
There are three rules in the file, do not delete, add or copy lines. Only replace xxxx with the correct value as appropriate. It is possible that not all "xxxxx" will be replaced.
Save the file with the same name.
Possible values to replace the "xxxxx":
8080
ALL
APPLY
false
MONITOR
Non-Prod
SecOps
smbhost
smbclient
TCP
True
3. An administrator wants to increase the performance of their Database virtual machine.
Database_VM has a database that is spread across three vDisks in the volume group Database_VM. The volume group is directly attached to the virtual machine. Previous performance analysis has indicated all storage requests are going to the same node. While this test environment has 1 node, the production environment has 3 nodes.
Configure the Volume Group Database_VM so that it's optimized for the user's VM and the production environment. The virtual machine has been powered off and moved to this test cluster for the maintenance work.
Note: Do not power on the VM.
4. Task 10
An administrator will be deploying Flow Networking and needs to validate that the environment, specifically switch vs1, is appropriately configured. Only VPC traffic should be carried by the switch.
Four versions each of two possible commands have been placed in Desktop\Files\Network\flow.txt. Remove the hash mark (#) from the front of correct First command and correct Second command and save the file.
Only one hash mark should be removed from each section. Do not delete or copy lines, do not add additional lines. Any changes other than removing two hash marks (#) will result in no credit.
Also, SSH directly to any AHV node (not a CVM) in the cluster and from the command line display an overview of the Open vSwitch configuration. Copy and paste this to a new text file named Desktop\Files\Network\AHVswitch.txt.
Note: You will not be able to use the 192.168.5.0 network in this environment.
First command
#net.update_vpc_traffic_config virtual_switch=vs0
net.update_vpc_traffic_config virtual_switch=vs1
#net.update_vpc_east_west_traffic_config virtual_switch=vs0
#net.update_vpc_east_west_traffic_config virtual_switch=vs1
Second command
#net.update_vpc_east_west_traffic_config permit_all_traffic=true
net.update_vpc_east_west_traffic_config permit_vpc_traffic=true
#net.update_vpc_east_west_traffic_config permit_all_traffic=false
#net.update_vpc_east_west_traffic_config permit_vpc_traffic=false
問題與答案:
| 問題 #1 答案: 僅成員可見 | 問題 #2 答案: 僅成員可見 | 問題 #3 答案: 僅成員可見 | 問題 #4 答案: 僅成員可見 |

下載最新試用版
1041位客戶反饋
我們對我們的產品非常有信心,所以我們不提供会给客户带去麻煩的產品。








192.91.144.* -
我已经通过了今天的 NCM-MCI-6.10 考試,谢谢你們提供的帮助,我很慶幸從 VCESoft 網站购买了這個学习指南,因为這個指南是非常简单易懂的,讓我輕松的通過了考試。